Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

1831MS Steartrimonium Methosulfate: Solid-Grade Specifications and Conditioner Evaluation

Abstract. 1831MS is listed as Steartrimonium Methosulfate and supplied as a white-to-faintly-yellow granular solid. The TDS reports 70–75% active content and recommends use in hair-care, hair-dye and perm products. This review explains active-basis dose calculations, the difference between supplier positioning and experimentally demonstrated outcomes, and a phase-appropriate screening plan for the solid grade.

Specification and identity

The 1831MS TDS gives active content 70.0–75.0%, amine hydrochloride and free amine ≤2.0%, and pH 5.0–8.0 in a 1.0% solution. The listed INCI is Steartrimonium Methosulfate. The physical form is granular, in contrast to the liquid 1831 chloride grade. The TDS describes antistatic and lubricating effects, combability, softness and applications that include conditioner, mask, colour-filling cream and perm products. A manufacturer should treat those functions as test endpoints rather than guaranteed finished-product outcomes.

Specification Reported value Why it matters
Active content 70.0–75.0% Commercial-grade percentage and active-matter percentage are different dose bases.
Amine hydrochloride and free amine ≤2.0% Check lot result and agreed method before release.
1% solution pH 5.0–8.0 Use the stated dilution basis, not a direct reading of the dry solid.
Appearance White to faintly yellow granules Check for lot consistency and correct storage before charging.
Package/storage 25 kg; ventilated, cool place Confirm current label, shelf life and site handling controls.

Active matter calculation

The TDS lists 0.5–3.0% for hair-care products, 1.0–3.0% for hair-dye products and 1.0–3.0% for perm products. If a 100 kg conditioner contains 1.0% supplied 1831MS, that is 1.0 kg of grade and approximately 0.70–0.75 kg active across the stated assay range. A 1.0 kg active target would therefore require about 1.33–1.43 kg of commercial material, depending on the actual assay. This is a mass-balance illustration, not an optimum level.

When comparing to 1831, state both the active basis and the rest of the carrier package. The 1831 TDS identifies 28–32% alcohol; the 1831MS TDS describes a granular solid and does not identify a corresponding alcohol carrier. Replacing one grade by equal as-supplied mass would therefore confound the cationic ingredient, physical form and carrier contributions.

Application function and evidence boundary

The 1831MS TDS presents the grade as a cationic material that can reduce static and friction, improve wet/dry combing and support hair-care and colour systems. The general hair-conditioning literature describes electrostatic association of cationic species with negatively charged sites on hair and hydrophobic interactions that can support lubrication. A 2025 comparative study tested behentrimonium chloride, behentrimonium methosulfate, cetrimonium chloride and stearylalkonium chloride; it shows that structure and counterion can matter under experimental conditions. It did not test 1831MS, so those results do not establish its performance or quantify an effect.

The TDS also uses phrases such as “filling gaps” and “barrier function.” A temporary surface deposit may improve feel, but these phrases should not be interpreted as restoration of damaged keratin or proven UV/heat protection unless the finished product is tested for those endpoints. Use the narrower, measurable endpoints first: wet combing, dry combing, static charge, friction or colour retention, depending on the product brief.

Bench evaluation for a granular grade

  1. Prepare a blank and a concentration series in the intended product category. Record the formula basis and the exact lot assay.
  2. Identify a practical incorporation method for the granular form. Log the actual temperature, charging sequence, mixing and time to uniformity because the TDS does not prescribe a universal process.
  3. Measure pH after the batch is prepared and equilibrated. Record appearance and viscosity with instrument, geometry, speed and temperature.
  4. For rinse-off conditioner, use matched tresses, a fixed dose, contact time and rinse procedure; measure wet-combing force and report replicate variation.
  5. For colour or perm systems, define a separate test protocol. Use the actual exposure sequence and a relevant control; do not infer performance from a conditioner-only test.
  6. Run the site’s physical-stability and package-compatibility checks before promoting a bench formula.

Process and quality questions

Review the particle/granule handling, dust control, moisture exposure, addition rate, heating need and cleanability at the intended scale. Set an incoming-material sampling plan and retain a lot sample. During scale-up, compare viscosity curves or torque trends instead of relying only on the final appearance. Ingredient change, mixing energy and cooling history can change the final texture of a surfactant/fatty-alcohol system.

For sourcing, request a current TDS, SDS and lot-specific CoA. Confirm whether assay method or pH method has changed between revisions. Maintain separate approvals for raw-material identity, finished-formula performance, safety and market compliance.

Set measurable acceptance criteria

Before the study, define what “low residue,” “smooth” or “low irritation” means for the intended product and which team owns the assessment. For combing, specify tress preparation, force metric and target comparison. For residue, define a repeated-use protocol and measurable endpoint. For compatibility, specify limits for pH, viscosity, appearance and storage. The TDS’s 0.5–3.0% hair-care range is an envelope for development, not evidence that every concentration meets every product target.

The document also lists dye and perm applications. These need separate protocols: record application order, dwell time and rinse conditions, then assess the finished formula. Ingredient-level statements cannot establish the safety or regulatory profile of the complete product.

For a granular grade, record charging rate, wetting behavior, mixing time and whether undissolved particles remain before cooling. Keep sample age consistent for viscosity comparison. Establish any heated process for the complete formula and consult the SDS and site procedure; do not infer processing temperature from the INCI name.

References

  1. Plant Chain, 1831MS Technical Data Sheet.
  2. Beck et al., Electrokinetic analysis reveals common conditioner ingredient interactions with human hair, International Journal of Cosmetic Science (2025); 1831MS was not directly tested.
  3. Gomes et al., On Hair Care Physicochemistry: From Structure and Degradation to Novel Biobased Conditioning Agents, Polymers (2023).

Explore 1831MS and request the current controlled specification before selecting a process window.