Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

300PR Specification Review: Connecting Solids, Composition and Functional Charge

Research question and grade facts

300PR is identified as Polyquaternium-30, an amphoteric terpolymer. The grade sheet reports typical solids 9–11%, pH 3–5 for a 1% solution at 25 °C and raw-material viscosity 2,000–12,000 mPa·s at 25 °C. A separate composition declaration may identify named polymer and preservative content for a specific revision. Confirm that revision and lot applicability. Total solids are not automatically equal to active polymer, charge equivalents or effective dose.

Mechanistic context

For a polyampholyte, the balance and accessibility of positive and negative groups can affect association with surfactants and surfaces. Two lots may share the same INCI and total solids but differ in molecular distribution or charge behavior. The TDS values provided do not resolve those variables, so formulation performance should be measured rather than inferred from solids alone.

Proposed experimental design

Request the current composition, CoA method, pH method, solids test and change-control information. Compare an approved retained lot and a candidate lot in the same simplified cleanser. Hold surfactant composition, salt, pH, water, addition order and mixing fixed. Measure appearance, conductivity, viscosity, dilution response and tress performance as separate endpoints. If the lot composition is unclear, use an as-supplied comparison and label the active normalization as unavailable.

Worked calculation

At a 1.00% commercial dose, the 9–11% solids range contributes 0.09–0.11% total solids to the formula. It does not establish that active polymer is 0.09–0.11% unless the supplier defines the assay that way. Do not convert the pH or viscosity values into charge or active content.

Interpretation and limitations

If two lots pass incoming solids but differ in the same finished formula across independent batches, ask the supplier whether polymer composition or test method changed. A measured charge titration may be informative if it is validated for the grade. Do not set a commercial acceptance limit from a single experimental lot.

Reproducibility and evidence boundary

Use independently prepared formula batches and independent tresses as the experimental units. Repeated readings from a single sample estimate measurement precision but are not independent replicates. Randomize sample order, blind treatment codes where sensory ratings are used, and define the primary outcome before reviewing results. Record raw-material lot and TDS revision, water quality, process temperature, mixing geometry and elapsed time. If different outcomes disagree, report each separately rather than combining them into one score. Repeat any decision-driving condition with a fresh preparation before changing a production formula.

Scale-up and publication standard

Conclusions apply only to the tested grade, lot, finished formula and conditions. A plausible mechanism is a hypothesis until directly measured. Confirm the key bench finding in a pilot or second hair/source lot when relevant. Preserve the method, raw readings, formula mass balance and supplier document with the batch record. The linked literature offers design context for related model systems; it should not be presented as direct performance data for 300PR Specification Review.

References and applicability