BTC95 vs LATC30 for Transparent Shampoo: Active Basis, Processing and Clarity Testing
Abstract. BTC95 and LATC30 are both presented for transparent-product use, but their supplied forms and assay ranges are very different. BTC95 is a high-purity powder with a TDS-described glycerol or propylene-glycol pre-dispersion route; LATC30 is a water-rich liquid at 29–31% active. This comparison treats clarity as a finished-formula measurement, not an automatic consequence of either ingredient. It also gives a test design that keeps active matter and carrier differences visible.
Compare what the TDS actually says
| Attribute | BTC95 | LATC30 |
|---|---|---|
| INCI | Behenoyl PG-Trimonium Chloride | Lauroyl PG-Trimonium Chloride |
| Form | Pale-yellow powder | Clear, colourless-to-light-yellow liquid |
| Active content | ≥99.0% | 29.0–31.0% |
| Other TDS limits | Free amine ≤1.5%; free fatty acid ≤1.0%; water ≤1.0% | Free fatty acid ≤1.2%; water 69.0–71.0%; alcohol-free stated |
| Shampoo use range | 0.30–0.80% | 0.20–0.80% |
| Clarity/process note | 1 part grade to 2.5 parts glycerol or propylene glycol; heat and stir until transparent, then add to hot water | TDS describes better water solubility and suitability for transparent products |
Normalize the formula basis
At 0.50% as supplied, BTC95 contributes at least 0.495% active. The same 0.50% charge of LATC30 contributes approximately 0.145–0.155% active. A nominal 0.15% active target would require about 0.152% BTC95 at the 99% minimum or roughly 0.484–0.517% LATC30 across its 29–31% range. These calculations compare mass fractions only; they do not assert that the two distinct molecules produce equivalent performance at equal active matter.
Include the carriers in the mass balance. The LATC30 TDS reports 69–71% water. BTC95’s transparent-shampoo note adds a polyol at a 1:2.5 ratio in that processing route. If one arm uses a polyol premix and the other uses a liquid aqueous grade, the polyol and water differences may affect clarity and viscosity. Balance those vehicle components in controls where possible and record any necessary adjustment.
What clarity depends on
Finished clarity can be altered by the cleansing surfactant blend, amphoteric content, electrolyte, pH, fragrance, polymer, temperature and addition sequence. A transparent incoming liquid does not demonstrate that a concentrated surfactant formulation will remain transparent. Similarly, the BTC95 pre-dispersion procedure is a supplier process instruction, not a guaranteed transmittance result. Establish the target’s optical criterion before screening: fixed path-length visual inspection, turbidity or light transmittance can be used if the method is controlled and reported.
Both TDS documents list a shampoo range that reaches 0.80%, but their actives differ substantially. Start with a practical dosage series within each grade’s range; then, if mechanism comparison is the goal, add a separate active-normalized series. Keeping these questions separate prevents a false conclusion based on equal supplied mass.
Controlled screening sequence
- Prepare one base shampoo without either conditioner and record its surfactant active matter, salt, pH, fragrance, polymer and baseline clarity.
- For the BTC95 arm, follow the TDS’s 1:2.5 material-to-polyol dispersion and heat until transparent. Record actual temperature, time and mixing conditions; these are not specified in the TDS.
- For the LATC30 arm, add the liquid by a documented sequence. The TDS does not prescribe order or temperature, so evaluate a controlled sequence rather than assuming one.
- Make at least three levels per grade, first on the as-supplied basis and then, if useful, at selected active-matter equivalents. Keep vehicle components balanced in the corresponding controls.
- Measure clarity immediately and after a fixed equilibration period. Recheck after project-defined temperature cycling and storage. Record haze, sediment, crystals and phase separation.
- Measure pH and viscosity at fixed conditions. Assess wet combing on matched tresses using the same wash, dose, contact, rinse and combing conditions.
Interpret the results without overclaiming
A grade can yield excellent clarity but modest combing improvement, or stronger combing performance with an unacceptable haze in a given base. Report each response separately. A 2025 comparative hair study showed that cationic surfactant structure affects deposition and wet combing, but it did not include BTC95 or LATC30. The article is a rationale for testing rather than a ranking of these materials. The current TDS claims and concentrations likewise do not replace a finished-product study.
For commercial selection, assess manufacturability as well: powder dispersion and charging for BTC95, liquid dosing and carrier-water control for LATC30, batch cycle time, cleaning, package compatibility and supply specification. Confirm that claims such as “transparent,” “low residue” and “low irritation” are supported for the final product and market.
How to interpret the comparison
BTC95 may meet an optical target after polyol pre-dispersion yet require a more involved charging step. LATC30 may be easier to meter because it is liquid, but still haze after electrolyte, fragrance or polymer addition. Both can pass clarity while differing in wet combing, viscosity or foam. Report which grade met each criterion and under which conditions rather than naming a universal winner.
After the initial compatibility window is understood, use a small factorial or sequential study to examine grade, active level and one key electrolyte or polymer condition. A confirmation batch should repeat the selected formula independently and, where possible, use a second raw-material lot. This separates repeatable behavior from a one-off batch result.
Before launch, confirm that the manufacturing instruction preserves the successful charging sequence, that the finished formula passes its shelf-life protocol and that product-page language does not promise more than the tested clarity range. Link raw-material and finished-product evidence by lot and formula identifier.
References
- Plant Chain, BTC95 TDS and LATC30 TDS.
- Beck et al., Electrokinetic analysis reveals common conditioner ingredient interactions with human hair, International Journal of Cosmetic Science (2025).
- Gomes et al., Physicochemical Aspects of the Performance of Hair-Conditioning Formulations, Cosmetics (2020).
BTC95 · LATC30 · Request lot-specific documents before running a comparative pilot.