Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

GX100 Steartrimonium Chloride Specifications, Performance and Uses

GX100 is an aqueous grade of Steartrimonium Chloride, a C18 quaternary ammonium conditioning ingredient. Its combination of active matter and water makes both values relevant when reformulating from a differently concentrated grade.

Technical specifications

Parameter Value
INCI / CAS Steartrimonium Chloride / 112-03-8
Appearance in the TDS Colorless and transparent to milky or flocculated
Active content 29.0–31.0%
Amine hydrochloride and free amine ≤2.0%
pH 3.0–6.0 in a 1.0% solution
Water 68.0–72.0%
Appearance in the website catalog Colorless to pale yellow liquid

Performance and formulation functions

The TDS describes softer feel, static control and easier combing as intended functions. A published conditioner patent includes a hair-tress wet-combing comparison with stearyl trimethyl ammonium chloride in one test formulation. The experiment illustrates one way to compare conditioning ingredients. Use a control in the target base to assess the GX100 grade, and confirm acceptable incoming appearance against the current release document.

Applications and use guidance

The TDS lists conditioners, masks, hair-color systems and perm applications. Normalize comparisons to the confirmed active content and account for the accompanying water in the formula. In a conditioner trial, monitor emulsion appearance, viscosity and wet combability. Evaluate processing and stability again when changing the raw material grade or concentration.

What surface-friction experiments show

Steartrimonium Chloride is a C18 quaternary ammonium surfactant, also described as stearyltrimethylammonium chloride. Fujii and colleagues tested this chemical on a film prepared from human hair keratin. Their measurements found concentration-dependent changes in friction and spectroscopic evidence consistent with adsorption. The film gave the researchers a controlled surface for comparison. Whole hair tresses add cuticle geometry, differences in damage and the effect of rinsing, so a commercial GX100 formulation should be evaluated using the intended substrate and treatment protocol. Original keratin-film adsorption and friction study.

Correct for the water carried by the liquid grade

At an illustrative 3.00% addition as supplied, the TDS values imply 0.87–0.93% Steartrimonium Chloride and 2.04–2.16% water in the batch. If comparing GX100 with a higher-active solid or paste, first match the target active content using the certificate of analysis. Then rebalance the water introduced by each ingredient. Document the comparison basis so that a viscosity or sensory difference can be interpreted alongside the actual active and water levels.

When inspecting incoming material, compare its appearance under the temperature and handling conditions in the agreed specification. Record any visible flakes or haze and whether the appearance changes after temperature equilibration. Check the signed acceptance specification and the lot certificate if the catalog appearance wording differs. Measure finished-product pH separately from the TDS 1% pH test.

Turn the friction question into a rinse-off test

Start with a base and at least two GX100 active levels in a low-viscosity rinse or a structured conditioner. Match the bulk pH, and keep fatty alcohol and oil constant within the structured series. Use the same treatment quantity, contact time and rinse conditions for each tress. Record peak wet combing force and total combing work when the instrument permits, since these capture different aspects of detangling. Check dry feel and flyaway separately under controlled humidity.

For a rinse designed to stay translucent, screen the final fragrance and any electrolyte package at concentrate and use dilution. For an opaque conditioner, check viscosity and phase stability after storage. Include repeated-use observations if evaluating an active increase, because a noticeable first-rinse effect and acceptable feel over multiple uses are distinct formulation goals.

Sources