K9-PG Hair Study: Separating Surface Deposition, Combing and Photoaging Measures
Research question and supplier parameters
K9-PG is Hydrolyzed Keratin PG-Propyl Methylsilanediol. The composition table reports 20–24% named component, 8–12% 1,3-propanediol, 0.88–0.92% phenoxyethanol and 30–32% total solids as a separate test. Nitrogen is ≥1.50%; pH is 4–7 in a 1% solution. These values are not interchangeable dose bases.
Mechanistic context
A recent primary study evaluated hydrolyzed keratin deposition and hair photoaging endpoints for a different preparation. Imaging or fluorescence can show material location, while combing measures frictional behavior and light exposure assays address other damage-related outcomes. One cannot be substituted for another.
Proposed experimental design
Use a base, K9-PG candidate and carrier-matched control on randomized tresses. Standardize dose, contact time, rinse, water and drying. Reserve separate tresses for surface/cross-sectional imaging and wet-combing. If evaluating light exposure, include protected and exposed matched controls and define the irradiation spectrum and dose. Validate any label or stain for interference with the keratin substrate.
Worked calculation or endpoint
At 2% K9-PG, named component input is 0.40–0.48% by the composition range, while total-solids input is separately estimated at 0.60–0.64%. The ranges describe different measures; do not add them or call the total-solids number active protein.
Interpretation and limits
A surface signal without a combing change supports deposition but not improved manageability. A combing change without a specific signal supports a mechanical response but does not identify its cause. Report each endpoint and the exact preparation tested; avoid generalizing findings from a different hydrolysate to K9-PG.
Repeatability and method reporting
Use independently prepared formula batches and tresses as experimental units. Repeated readings from one sample assess instrument precision, not independent formulation variability. Randomize sample order, blind sensory codes when possible, define the primary outcome in advance and retain raw observations. Record instrument geometry, sample temperature, water source, material lot, formula mass balance and elapsed time. Report conflicting responses separately; do not collapse clarity, viscosity, deposition and combability into one undocumented performance score.
Transfer to a product decision
Confirm the key result with a fresh preparation and, when relevant, another lot or substrate source. Conclusions apply to the tested K9-PG Hair Study formula and conditions. A proposed mechanism remains a hypothesis unless the mechanism itself was measured. The linked papers and official records provide context for method selection; they are not direct performance studies on this commercial grade. Preserve the supplier document revision and study protocol with any technical or marketing decision.
References and applicability
- K9-PG supplier composition and TDS. Confirm revision-controlled table and lot CoA.
- Primary study: hydrolyzed keratin hair deposition and photoaging. Different hydrolysate and test conditions; method context only.
- Hair electrokinetics and conditioner combing study. Primary work on other conditioners; illustrates distinct endpoints.
