Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

K9-PG Analytical Review: Why Nitrogen, Solids and Keratin Content Are Not Interchangeable

Purpose

A formulation calculation can look precise while combining three unlike measures: a named ingredient percentage, total solids and a nitrogen limit. For K9-PG, those values describe different aspects of the supplied liquid. The goal here is to establish what can be calculated directly and what requires a validated analytical relationship.

Reported grade information

The composition table identifies 20–24% Hydrolyzed Keratin PG-Propyl Methylsilanediol, 8–12% 1,3-propanediol, 0.88–0.92% phenoxyethanol and 62.96–71.04% water. Separate test items include solids at 30–32%, nitrogen at no less than 1.50%, and pH 4–7 for a 1% dilution. The composition percentage is the direct basis for estimating that named component. Total solids is a gravimetric residue test. Nitrogen is an elemental assay with no published conversion factor in the supplied documents.

A bounded calculation

For a 1.00 kg batch with 2.00% K9-PG, commercial ingredient mass is 20.0 g. The composition range yields 4.0–4.8 g of the named silanized keratin component, while propanediol contributes 1.6–2.4 g and phenoxyethanol 0.176–0.184 g. The total-solids test range yields 6.0–6.4 g of measured solids. These are parallel calculations, not additive components; adding them together would double-count. The water contribution ranges independently from 12.592–14.208 g. Obtain lot-specific values if the formulation requires tighter accounting.

What nitrogen can and cannot show

A minimum nitrogen result can serve as a supplier quality parameter under a specified test, but it does not identify which molecule contains that nitrogen or its molecular distribution. To convert nitrogen into a keratin-component estimate, the supplier would need a validated and lot-appropriate conversion factor that accounts for composition and analytical recovery. Without it, do not calculate keratin mass from nitrogen or use it as an equal-active substitution basis. Ask for method, dry/wet basis, reference material and uncertainty.

Analytical transfer into finished products

If measuring finished-product solids, define the drying method and account for the conditioner base residue. A blank formula and spike recovery are needed because oils, surfactants and salts also contribute residue. If the target is the keratin-derived component on hair, total residue is not specific enough. Fluorescent labeling, spectroscopy or mass-spectrometric surface methods may be considered only after validating that the method distinguishes product from substrate and that labeling or extraction does not change the analyte behavior.

Literature limits

Primary work on hydrolyzed keratin has reported hair deposition and fiber-surface observations for a different ingredient preparation. It supports measuring the target on hair and combining imaging with functional endpoints; it does not convert K9-PG nitrogen, solids or composition into an efficacy claim. Report formula performance separately from raw-material identity and assay results.

Recommended supplier questions

Request the revision-controlled composition, definitions for total solids and nitrogen, test methods, lot CoA, analytical uncertainty and any validated conversion between nitrogen and the named component. For substitution or longitudinal trend, request retained-lot comparisons. Meanwhile, calculate only values directly supported by the composition table, label range-based estimates clearly, and use independent formula controls to test function.

References and applicability