Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

LATC30 Clear Shampoo: A Robust Optical and Temperature Stability Protocol

Research question

A clear product can become hazy during storage, but a single visual check cannot identify whether the cause is temperature-dependent surfactant structure, fragrance solubilization, electrolyte sensitivity, entrained air or a colored raw material. This protocol treats clarity as a measured property and links it to a defined formula and temperature history.

Ingredient information

The supplier identifies LATC30 as Lauroyl PG-Trimonium Chloride, a cationic surfactant grade promoted for transparent cleansing systems. Use the latest grade-specific TDS and CoA for active content, carrier and test conditions; product-page descriptions should not substitute for a batch-specific certificate. The neat or diluted appearance of the material is not a guarantee that a finished formula will remain clear. Finished pH and viscosity must be measured on the complete system.

Optical causes

Transmittance combines absorption and scattering. A fragrance tint or polymer color may lower transmission without forming particles; bubbles and dust can create scattering; a temperature-driven phase shift can create reversible haze. A stable single-wavelength reading without matched blanks cannot distinguish these. Use the same cuvette path length, wavelength, orientation, sample temperature and time after mixing. Record an instrument blank and a formula control. A standardized dark-field photograph can supplement, but not replace, the instrument result.

Controlled screening plan

Prepare a base, a LATC30 formula and a carrier-matched blank when composition is known. Keep surfactant ratios, fragrance, preservative and water source constant. Screen only the pH and electrolyte span relevant to the intended product. Add each electrolyte from a standardized stock by mass and log the final conductivity; conductivity is not equivalent to a direct salt assay in a multicomponent solution. For fragrance, compare a fragrance-free control and the intended fragrance at its planned level. Make independent batches at key boundaries instead of relying on serial additions to one beaker, which can confound mixing and sample history.

Temperature cycling and sampling

After a defined equilibration period, measure a room-temperature baseline, store sealed samples at preselected cool, ambient and warm conditions appropriate to the product program, then return them to the same measurement temperature before comparing. Record reversible haze during the temperature hold separately from haze remaining after re-equilibration. Avoid calling one short cycle a shelf-life study. Add freeze-thaw or centrifuge screens only when relevant to distribution and package risk, and interpret them as stress tests. Sample from the same position and allow bubbles to dissipate without changing its thermal history.

Functional performance

Clarity is a product requirement, not a cleansing efficacy measure. In a rinse-off application, compare soil removal, lather, rinse feel and hair combing under controlled substrate and water conditions. An optical improvement accompanied by poorer lather is not an unqualified product improvement. If evaluating hair, distinguish wet-combing forces from dry feel and test the actual final formula at a consistent dose. Literature on cationic surfactant deposition and conditioner response supports endpoint-specific testing, but results for a different surfactant or model formula do not establish a LATC30 result.

Decision rules

If the fragrance-free sample remains clear but the fragranced sample clouds, focus on fragrance solubilization and its interaction with the complete surfactant base. If all arms cloud only when cold and clear after returning to the baseline temperature, document reversible temperature sensitivity and assess real distribution exposures. If the LATC30-free blank behaves the same, do not attribute the result to LATC30. Repeat any apparent pass near the operational boundary with fresh batches and actual manufacturing water. Retain a clear acceptance method: for example a specified transmittance band plus absence of visible separation under a fixed inspection protocol.

References and applicability