How to Record the Mass of a Phospholipid Blend in a Pilot Batch
When a viscous liquid is weighed into a separate cup, some material can stay behind during transfer. A pilot worksheet can capture both the mass taken from the source container and the mass that reaches the batch. That distinction helps the lab explain differences between a bench sample and a larger pilot.
Identify the blend before setting up the transfer
The OADP technical data sheet describes a clear, viscous liquid ranging from colorless to pale yellow. Record the commercial blend name and lot on the worksheet. Use a clean transfer vessel suited to the quantity and check that the balance can resolve differences that matter to the trial. Follow the material’s current handling instructions and record any preparation specified for the trial.
Measure what leaves the transfer vessel
- Record the empty mass of the transfer vessel and any tool that will be weighed with it.
- Weigh the loaded vessel and record the gross mass before transfer.
- After transfer, reweigh the vessel with the same tool and any residue still present. Subtract the second gross mass from the first.
- Record spills, material left on other tools or any rinse added to the batch. Where practical, check the receiving vessel’s mass increase against the calculated transfer.
For example, if the loaded vessel weighs 128.4 g before transfer and 113.8 g afterwards, 14.6 g left the vessel. That value represents the mass delivered only if the full transfer reached the batch. A worksheet can keep the intended mass, calculated transfer and verified received mass in separate fields.
Carry the record into the next scale
Record the tool, vessel, transfer sequence and any material or rinse used to complete the addition. If the next pilot uses a pump or a different vessel, agree in advance on how the received mass will be checked. Compare the measured material balance with the trial’s tolerance and log any adjustment before recording the actual batch composition.
See the Technical Center for more formulation guidance.
Appearance reference: OADP technical data sheet. The weighing values illustrate the worksheet.