Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

PQ-28 Application Boundary: Comparing Rinse-Off and Leave-On Film Delivery

Research question and grade facts

PQ-28 is Polyquaternium-28 with supplier solids 19–21%, raw-material pH 5–8 at 1% dilution and typical viscosity 20,000–60,000 mPa·s at 25 °C. These parameters describe the supplied grade and do not establish a finished-product use level or water-resistance claim.

Mechanistic context

Leave-on and rinse-off products have different contact time and removal conditions. A film seen after drying in a leave-on gel cannot be assumed to remain after shampooing. Product format, solids deposited per gram of hair and drying environment all influence apparent performance.

Proposed experimental design

Prepare a single standardized PQ-28 film-forming base and apply it to matched tresses at a fixed mass. Divide specimens into leave-on, water-rinse and shampoo-rinse arms. Match dose, drying, humidity and handling. Record curl retention, combing, film residue and flaking. Add vehicle-only controls for every exposure arm. Use separate tresses for analytical residue where destructive.

Worked calculation

For a 0.50 g product application to 5.0 g dry hair, the as-applied product loading is 0.10 g/g hair. The solids deposited before rinsing are not necessarily the retained solids after rinse. A validated residue method is needed to quantify retention.

Interpretation and limitations

If leave-on performance is strong but rinse-off performance falls, report the format boundary rather than generalizing to both uses. If water rinse differs from shampoo rinse, surfactant removal contributes. Confirm across a second hair lot and do not describe a cosmetic film as structural repair.

Reproducibility and evidence boundary

Use independently prepared formula batches and independent tresses as the experimental units. Repeated readings from a single sample estimate measurement precision but are not independent replicates. Randomize sample order, blind treatment codes where sensory ratings are used, and define the primary outcome before reviewing results. Record raw-material lot and TDS revision, water quality, process temperature, mixing geometry and elapsed time. If different outcomes disagree, report each separately rather than combining them into one score. Repeat any decision-driving condition with a fresh preparation before changing a production formula.

Scale-up and publication standard

Conclusions apply only to the tested grade, lot, finished formula and conditions. A plausible mechanism is a hypothesis until directly measured. Confirm the key bench finding in a pilot or second hair/source lot when relevant. Preserve the method, raw readings, formula mass balance and supplier document with the batch record. The linked literature offers design context for related model systems; it should not be presented as direct performance data for PQ-28 Application Boundary.

References and applicability