PQ-47 Dose Basis: Comparing As-Supplied, Solids-Normalized and Finished-Use Responses
Research question and grade facts
PQ-47 TDS lists 18–22% total solids, pH 3–5 in a 1% aqueous solution at 25 °C and typical raw-material viscosity 2,000–12,000 mPa·s at 25 °C. Confirm the lot result and composition. Total solids are not necessarily active polymer content; raw-material viscosity is not finished-shampoo viscosity.
Mechanistic context
An as-supplied dose reflects manufacturing practice, while solids normalization controls one measured property. Neither guarantees equal charge equivalents or molecular structure. Repeated-wash response can include ongoing deposition and removal, so performance after one wash should not be generalized to cumulative use.
Proposed experimental design
Run one block at equal commercial dose and another at equal measured solids, using the same shampoo base. Include a polymer-free control. Keep pH, salt, surfactants and water constant. Measure formula viscosity under defined shear and run a standardized wash series on matched tresses, including an arm that switches to base after initial PQ-47 exposure.
Worked calculation
A 2.00% dose of a 20% solids lot contributes 0.40% total solids to the finished formula. A lot at 18% contributes 0.36% at the same as-supplied level. To match 0.40% solids with the 18% lot, use 2.22% as supplied, subject to exact CoA and final-mass adjustment.
Interpretation and limitations
If equal-as-supplied samples differ but solids-matched samples converge, total solids may explain part of response. If they remain different, investigate unmeasured composition and method. Report viscosity, wet combing, dry feel and residue as separate endpoints, with each wash count stated.
Reproducibility and evidence boundary
Use independently prepared formula batches and independent tresses as the experimental units. Repeated readings from a single sample estimate measurement precision but are not independent replicates. Randomize sample order, blind treatment codes where sensory ratings are used, and define the primary outcome before reviewing results. Record raw-material lot and TDS revision, water quality, process temperature, mixing geometry and elapsed time. If different outcomes disagree, report each separately rather than combining them into one score. Repeat any decision-driving condition with a fresh preparation before changing a production formula.
Scale-up and publication standard
Conclusions apply only to the tested grade, lot, finished formula and conditions. A plausible mechanism is a hypothesis until directly measured. Confirm the key bench finding in a pilot or second hair/source lot when relevant. Preserve the method, raw readings, formula mass balance and supplier document with the batch record. The linked literature offers design context for related model systems; it should not be presented as direct performance data for PQ-47 Dose Basis.
References and applicability
- PQ-47 grade documents. Use current lot-specific CoA.
- Conditioning polymers in shampoo: efficacy and methods. Primary work on polymer-conditioned shampoo endpoints; not PQ-47.
- XRF study of shampoo-mediated silicone deposition. Primary example of analyte-specific deposition measurement with another polymer.