Skip to content
Guangzhou Plant Chain Beauty Technology Co., Ltd. Serving customers across 18 countries · sales@cationicsurfactants.com
Plant Chain company logoPlant ChainCationic Surfactants

All Insights

Polyquaternium-47: Normalizing Solids and Carrier Effects in Shampoo Trials

Question

When two PQ-47 lots or formula levels give different shampoo behavior, is the cause polymer quantity, supplied carrier, or the surfactant matrix? An as-supplied dose alone cannot answer this if the material contains substantial water or other constituents. The first task is to identify what the assay actually measures.

Specification interpretation

The supplier sheet for this grade identifies Polyquaternium-47 and lists 18–22% solids, pH 3–5 for a 1% solution at 25 °C, and typical viscosity 2,000–12,000 mPa·s at 25 °C. Treat these as raw-material values under the stated test conditions. The source sheet does not establish that all measured solids are active polymer. Confirm the lot composition and method before calculating active polymer mass. The diluted raw-material pH is not a finished-shampoo pH target.

Mass-normalization example

For a 100 g shampoo screen, 1.00 g of supplied material at 18–22% solids contributes 0.180–0.220 g total solids. If two lots have different confirmed solids, use actual lot results to make a solids-matched comparison. If active polymer fraction is separately disclosed, calculate active mass independently. Maintain a second as-supplied-dose arm if the goal is to reproduce manufacturing practice. Adjust formula water to maintain exact final mass and account for all confirmed carrier contributions.

Formulation controls

Prepare a surfactant base control without PQ-47 and a candidate formula with it. When carrier ingredients are known, include a carrier-matched control. Hold surfactant ratios, salt, pH, perfume, preservative and mixing fixed. If viscosity is adjusted after polymer addition, report the adjustment and test a separate arm with the same thickener change. Check appearance immediately and after equilibration. Measure pH, conductivity, transmittance and viscosity using documented conditions. Sample after deaeration and ensure both formulas have comparable rest time.

Deposition and conditioning endpoints

A published X-ray fluorescence study examined the effect of a cationic cellulose polymer, Polyquaternium-10, on dimethicone deposition from model shampoo. This provides precedent for measuring an ingredient deposition endpoint rather than treating cationic polymer presence as proof of deposition. PQ-47 is chemically distinct, and dimethicone deposition does not establish PQ-47 deposition or a particular hair feel. Choose a validated analytical marker for the target of interest, test recovery and blanks, and use separate matched tresses for mechanical combing.

Tress and wash protocol

Randomize tresses by source and damage state. Use fixed hair mass, prewetting, dose, massage duration, rinse flow, water temperature and drying. Collect samples at the first wash and after a defined repeated-wash series if accumulation or removal is relevant. Include the blank base at every wash count. Measure wet-combing force-distance response, dry feel and any validated residue signal separately. If comparing wash-off, specify rinse volume and duration precisely. Multiple measurements on one tress are repeated observations, not independent tress replicates.

Interpretation

If the viscosity shifts while appearance and tress endpoints do not, treat rheology as a processing outcome rather than proof of conditioning. If deposition is measurable but combing does not change beyond variability, report both results without selecting only the favorable endpoint. If a difference disappears after carrier matching, the carrier likely deserves further investigation. Confirm conclusions with independent batches and another hair lot before generalizing.

References and applicability