Polyquaternium-47 Repeated-Wash Study: Retention, Removal and Performance
Research question
Does continued use of a PQ-47-containing shampoo change an objective hair response, and does any measured signal remain after the formula is withdrawn? These questions are different. Repeated application measures net deposition and removal under continued use; withdrawal measures persistence under a later cleansing sequence. Neither can be inferred from a single-wash beaker test.
Starting material and controls
The PQ-47 TDS lists 18–22% solids, pH 3–5 in a 1% solution at 25 °C and typical raw-material viscosity 2,000–12,000 mPa·s at 25 °C. Obtain the CoA and composition statement for the test lot. A 1.00 g addition to a 100 g batch contributes 0.180–0.220 g total solids by the specification range, not necessarily that mass of active polymer. Prepare the candidate, a polymer-free base and a carrier-matched control where possible. Keep wash base, pH, surfactants, viscosity adjustments and fragrance constant.
Study arms
Use separate groups of randomized tresses. One group receives the matched base at every wash. A second receives PQ-47 shampoo at every wash. A third receives PQ-47 on the first wash and the matched base thereafter. If persistence after several uses matters, add a fourth group that switches only after a predefined run of candidate washes. At each sampling point all groups should have the same total wash count. Use fresh tresses for each destructive chemical analysis and reserve other tresses for combing tests.
Wash control and measurements
Define hair mass, prewet time, formula mass per hair mass, massage strokes, contact time, rinse flow, water hardness and temperature. Standardize drying and storage between cycles. Assess wet-combing work and peak force separately, with instrument settings and tress moisture recorded. If dry feel or volume matters, use blinded ratings and a prespecified scoring scale. Measure a chemical residue only with a validated method capable of distinguishing PQ-47 from hair and the base. Validate spike recovery, blank response, extraction losses, quantification limit and sample stability.
Why analytical evidence matters
The published X-ray fluorescence method in a Polyquaternium-10/dimethicone shampoo study quantified silicone deposition, not polymer deposition. The experimental lesson is to select a marker matched to the analyte. XRF may not be suitable for a polymer lacking a unique measurable element. A fluorescent label can alter polymer behavior, so labeled-polymer methods require validation that the label does not change solubility, charge or deposition. Avoid using a generic residue mass as a direct measure of PQ-47 without specificity.
Analysis plan
For each endpoint, plot response against cumulative wash count and show individual tress trajectories where repeated measurement is nondestructive. Compare arms at equal wash counts. The continuing-use arm estimates response under ongoing application. The withdrawal arm tests how response changes after dosing stops. If wet-combing improves while the analytical signal is below its quantification limit, report an instrumentally observed combing difference without a deposition claim. If measured residue increases but combing worsens or remains unchanged, report the divergence rather than collapsing them into a single “conditioning” score.
Conclusion boundary
Results apply to the formula, lot, wash protocol and hair source tested. Repeat across batches and at least one additional tress lot before describing a robust trend. The intended claim should match the endpoint: “reduced wet combing work under this protocol” is narrower and more verifiable than “long-lasting repair.” Document any sensory or breakage outcomes separately and avoid biological or permanent-damage claims unsupported by the study.
References and applicability
- Plant Chain PQ-47 specification portal. Supplier material reference; verify lot-specific method and composition.
- Gruber et al., cationic polymer effect on silicone deposition from shampoo. Primary analytical method example involving PQ-10 and dimethicone, not PQ-47.
- Tham et al., hair adsorption, electrokinetics and wet combing. Primary study with distinct adsorption and mechanical endpoints; chemistry differs from PQ-47.
